SDC · Electrified hardware
SDC LR100 QuietDuo Retrofit Electric Latch Retraction Kit for Exit Devices, 24 V DC
The SDC LR100 QuietDuo is a motorized kit that goes into the rail of an exit device already on the door. On a signal from an access control system or a remote control device it retracts the latch, and on most kits pulls the push pad into the dogged position, so the door works push and pull. We quote SDC's kits for Adams Rite®, Arrow®, Cal-Royal, Detex, Jackson, PHI (Precision) and Yale devices, and each runs on 24 V DC.
- 24 V DC
- plus or minus 10 percent; 200 mA continuous
- Retrofit kit
- fits in the rail; the device stays on the door
- Motorized
- retracts the latch; most kits also dog the push pad
- Grade 1
- ANSI/BHMA A156.3; UL 305, UL 10C (SDC)
Every part number is priced on request, within one business day.
- Stocked items ship by the next business day after payment, with next-day air on request; special orders ship on the lead time we quote. Ground delivery in the lower 48 states. No shipping to Alaska, Hawaii or Puerto Rico.
- Exit device, opening width and 24 V DC supply confirmed in writing before anything ships
- No account and no minimum order. Shipping, returns and warranty terms.
Which SDC LR100 part number do I need?
Find your exit device's maker and model in the table: each LR100 kit fits only the devices SDC lists for it, on the opening widths it names. Then add the power supply SDC recommends: the 602RF for one door with any kit here except the LR100ARK, which needs the 631RF.
| Part number | Exit device | Fits (as SDC lists) | Opening | Retracts | Availability | Price | Quote |
|---|---|---|---|---|---|---|---|
| LR100ARK | Adams Rite | 8800, 3700 rim; 8100, 8200, 3100 SVR; 8500, 8600, 3600 CVR | 36 to 48 in | Latch only, not the push pad | Stocked | On request | Get a price |
| LR100AWK | Arrow | S1250 rim; S1150 SVR | 36 to 48 in | Latch and push pad | Special order | On request | Get a price |
| LR100CAK-EMAlso written LR100CAKEM | Cal-Royal | 2200, F2200, 9800, F9800 rim; 2260, F2260, 9860, F9860 SVR | 36 in | Latch and push pad | Stocked | On request | Get a price |
| LR100CAK-9800Also written LR100CAK9800 | Cal-Royal | GLS9800 rim; GLSCVR9800 CVR | 36 in | Latch and push pad | Special order | On request | Get a price |
| LR100DXK | Detex | 10, 40 rim; 20, 50 SVR; 80, 81, 62, 63 CVR | 36 in | Latch and push pad | Stocked | On request | Get a price |
| LR100JAK | Jackson | 2095 rim; 2085 CVR | 36 in | Latch and push pad | Stocked | On request | Get a price |
Show all 8 part numbers
| Part number | Exit device | Fits (as SDC lists) | Opening | Retracts | Availability | Price | Quote |
|---|---|---|---|---|---|---|---|
| LR100PDK | PHI (Precision) | 2100, 2400, 5100 rim; 2200LBR, 5200LBR SVR; 2800LBR, 2600 CVR | 36 to 48 in | Latch and push pad | Special order | On request | Get a price |
| LR100YDK | Yale | 7100, 7100-2, 7200 rim; 7110, 7210 SVR; 7120, 7220 CVR | 36 to 48 in | Latch and push pad | Stocked | On request | Get a price |
Every row is a SDC part number. Stocked means a US distributor holds it and it ships the same or next business day after payment; special order means it ships on the lead time we quote. For 5 or more of one part we confirm stock, lead time and the total in writing.
Ordering several of one part, or more than one part number? List each part number and quantity, or send your door list, and we quote the lot within one business day.
Send a list or door listHow the part number is built
Every SDC LR100 part number starts LR100 and names the exit device it is made for: LR100YDK is the kit for Yale 7100 and 7200 family devices on 36 to 48 in openings, and LR100YDK-EM is its two-piece version for 30 in openings. Choose by the maker and model on your device and the width of the opening.
Kits on this page
LR100ARKAdams Rite 8800 and 3700 families, 36 to 48 inLR100AWKArrow S1250 and S1150, 36 to 48 inLR100CAK-EMCal-Royal 2200 and 9800 families, 36 in, two-pieceLR100CAK-9800Cal-Royal GLS9800, 36 inLR100DXKDetex 10, 20, 40, 50, 62, 63, 80 and 81, 36 inLR100JAKJackson 2095 and 2085, 36 inLR100PDKPHI (Precision) 2100, 2400 and 5100 families, 36 to 48 inLR100YDKYale 7100 and 7200 families, 36 to 48 in
Related SDC kits we quote
-EMTwo-piece version, with the controller board outside the rail: LR100ARK-EM and LR100YDK-EM for 30 in openingsLR100AWK-ED910Arrow ED910, 36 inLR100Y6KYale 6100ED, 36 to 48 in (LR100Y6K-EM for 30 in)
SDC writes the series name QuietDuo, and distributors often write Quiet Duo. SDC makes LR100 kits for other exit devices too. Send the make, model and opening width of yours and we quote the kit SDC lists for it within one business day.
What are the SDC LR100 specifications?
The SDC LR100 is a motorized retrofit electric latch retraction kit that runs on 24 V DC, plus or minus 10 percent, at 200 mA continuous. SDC lists UL 305 panic hardware, UL 10C, ULC-S104 and ANSI/BHMA A156.3 Grade 1 among its certifications.
| Works with | The exit devices SDC lists for each kit, in the part table above. SDC says the kits retrofit those devices without removing the device from the door |
|---|---|
| Input | 24 V DC, plus or minus 10 percent; red positive, black negative |
| Current draw | 200 mA continuous (SDC datasheet and installation sheets) |
| Latch retraction | Motorized. The motor retracts the latch and pulls the push pad into the dogged (depressed) position, for momentary or sustained push and pull operation. The LR100ARK retracts the latch only, not the push pad |
| SDC power supply | 602RF for a single door; 602RFUR1 or a 634 series supply for a simultaneous pair. The LR100ARK needs the 631RF instead, or the 631RFUR1 or a 634 series supply for a pair |
| Certifications | UL 305 panic hardware; UL 10C positive pressure fire tests of door assemblies; ULC-S104 fire tests of door assemblies; ANSI/BHMA A156.3 Grade 1 (SDC datasheet) |
All 13 specifications
| UL categories (SDC) | All LR100 and LR100-EM units: GWVW.R26978 and GWVW7.R26978, accessories for single-point locks and latches and fire exit hardware; GXHX.R20647, fire exit hardware; FVSR.SA32359, panic hardware; FVSR2.SA32359, panic hardware component |
|---|---|
| Construction | LR100: one unit housed in the rail of the device, behind the access cover. LR100-EM: two pieces, with the controller board outside the rail, which SDC says gains up to 1 in of room in the device |
| Opening widths | 36 in: LR100CAK-EM, LR100CAK-9800, LR100DXK and LR100JAK. 36 to 48 in: LR100ARK, LR100AWK, LR100PDK and LR100YDK. For 30 in openings SDC makes LR100ARK-EM and LR100YDK-EM |
| Pair of doors | No door sequencer is needed for a pair of manual doors on a suitable power supply (SDC) |
| Another maker's supply | Linear, regulated and filtered, rated at least 2 A per LR100 kit (SDC recommendation) |
| Dogging | Any existing mechanical dogging is removed from the device when the kit goes in (SDC installation sheets) |
| Made by | Security Door Controls (SDC), Camarillo, California |
From SDC's own documents, listed under Documents. Last checked .
Will the SDC LR100 fit my door?
An LR100 kit fits only the exit devices SDC lists for it, by the maker and model on the device and the width of the opening. Send a photo of the device and its label and we confirm the kit in writing before anything ships.
Adams Rite (LR100ARK)
SDC lists the LR100ARK for Adams Rite 8800 and 3700 rim devices, 8100, 8200 and 3100 surface vertical rod (SVR) devices and 8500, 8600 and 3600 concealed vertical rod (CVR) devices, on 36 to 48 in openings. It retracts the latch only, not the push pad, and SDC says it needs the 631RF power supply. A 30 in opening takes the LR100ARK-EM, which SDC also lists for the 8700 rim device.
Arrow (LR100AWK)
SDC lists the LR100AWK for the Arrow S1250 rim device and S1150 SVR device on 36 to 48 in openings. The Arrow ED910 takes a different kit, the LR100AWK-ED910, which we quote on request.
Cal-Royal 2200 and 9800 (LR100CAK-EM)
SDC lists the LR100CAK-EM for Cal-Royal 2200, F2200, 9800 and F9800 rim devices and 2260, F2260, 9860 and F9860 SVR devices on a 36 in opening. It is a two-piece kit: SDC's wiring drawing puts its controller board in the box of an SDC 600 series power supply, wired to the kit in the door through a power transfer hinge.
Cal-Royal GLS9800 (LR100CAK-9800)
SDC lists the LR100CAK-9800 for the Cal-Royal GLS9800 rim device and its CVR version on a 36 in opening. SDC's documents write that CVR model three ways (GLSCVR9800, GLSVR9800 and GLSCVR9860), so send a photo of the label and we confirm the kit in writing.
Detex (LR100DXK)
SDC lists the LR100DXK for Detex 10 and 40 rim devices, 20 and 50 SVR devices and 80, 81, 62 and 63 CVR devices on a 36 in opening. A Detex Value Series device needs a modified cover: order Detex part 100518-11, or modify the existing cover as SDC's installation sheet shows.
Jackson (LR100JAK)
SDC lists the LR100JAK for the Jackson 2095 rim device and 2085 CVR device on a 36 in opening. The kit replaces the push bar end cap with its own End Cap 7194 and comes with a new cover, and on a vertical rod device the top strike is replaced with the ST8P strike in the kit.
PHI Precision (LR100PDK)
SDC lists the LR100PDK for PHI (Precision) 2100, 2400 and 5100 rim devices, 2200LBR and 5200LBR SVR devices and 2800LBR and 2600 CVR devices on 36 to 48 in openings. Its installation sheet names the 2101, 2201, 2400, 2600, 2801, 5100 and 5200. This is the Precision 2100, a different device from the Accentra™ 2100.
Yale (LR100YDK)
SDC lists the LR100YDK for Yale 7100, 7100-2 and 7200 rim devices, 7110 and 7210 SVR devices and 7120 and 7220 CVR devices on 36 to 48 in openings, and the LR100YDK-EM for 30 in openings. SDC lists no LR100 kit for the Accentra 2100 exit device, formerly the Yale 2100, so we do not offer one for it.
Device cut down to fit
SDC warns that a 42 or 48 in device modified to fit a 36 in or smaller opening may not have room for the kit. Measure from the end of the touchpad to the end rail and send us the figure with a photo, and we check it with SDC's sheet before anything ships.
Vertical rod device
The rods have to be adjusted after the kit goes in: SDC has the installer energize the kit so the latch is dogged down, then reconnect the rods and set them.
Power
Every kit runs on 24 V DC. SDC recommends its 602RF for a single door, and the 602RFUR1 or a 634 series supply for a simultaneous pair. The LR100ARK needs the 631RF, or the 631RFUR1 or a 634 series supply for a pair. With another maker's supply, SDC recommends a linear, regulated and filtered supply rated at least 2 A per kit.
Fire-rated exit device
SDC describes the kits as being for panic and fire rated exit devices and lists UL 305, UL 10C and ULC-S104 among their certifications. Whether and how a kit may be used on your fire-rated door is for your Authority Having Jurisdiction (AHJ).
A device not listed here
SDC makes LR100 kits for other exit devices. Send the make, model and opening width, or a photo of the device and its label, and we quote the kit SDC lists for it.
Electric latch retraction on doors people exit through, and on fire-rated doors, is covered by building and fire codes. Whether this kit may go on your exit device and door is a code question. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.
How do I install and wire the SDC LR100?
An SDC LR100 kit goes into the rail of the exit device already on the door: the cover or end cap comes off (more on some devices), any existing dogging comes out, the kit is fixed in place, and it is wired to 24 V DC, red positive and black negative.
Before you start
Each kit has its own SDC installation sheet, listed under Documents. SDC's sheets for every kit here except the LR100JAK warn that a 42 or 48 in device cut down for a 36 in or smaller opening may lack room, so measure from the end of the touchpad to the end rail first.
Dogging
SDC's sheets have any existing mechanical dogging removed from the device before the kit goes in.
Wiring
24 V DC, plus or minus 10 percent: red to positive, black to negative. On the LR100CAK-EM the controller board goes in the SDC 600 series power supply box, and 8-conductor, 18 to 22 AWG jacketed cable, 100 ft at most, runs from it through a power transfer hinge to the kit's supplied pigtail, colors matched at each end.
Vertical rods
Energize the kit so the latch is dogged down, then reconnect the rods and adjust them, as each sheet describes. The Jackson kit also replaces the top strike with its ST8P.
Jackson 2095 and 2085
Replace the push bar end cap with the kit's End Cap 7194, fit the roller clevis over it and lock it with the two supplied set screws, then fit the new cover and end caps.
Detex Value Series
The cover has to be modified: order Detex part 100518-11, or remove the metal inserts, snip off the ribs and cut out the front wall of the existing cover, as SDC's sheet shows.
Adams Rite
Assemble the kit's brackets for the device length, fit the bracket assembly over the push bar support brackets and attach it to the device's linkage, then power the kit to draw the sliding latch bracket open and lock it with the set screws. Rim and vertical rod devices have separate SDC sheets.
Yale and PHI Precision
Both kits work through a linkage. On the Yale device it hooks to the push bar's bottom cross bar and is pinned to the kit with a grooved clevis pin and retaining clip. On the Precision device the kit fixes to the device with two supplied screws.
From SDC's installation sheet for each kit and its LR100 datasheet, all listed under Documents. Follow the sheet that comes with the kit.
What else does the SDC LR100 need?
Every LR100 kit needs a 24 V DC supply and a signal to release it, from an access control system, a remote control device or a building automation system. These are the SDC supplies SDC names for the kits, and its request-to-exit (REX) and latch status (LS) monitoring kits for devices on this page.
Show all 11 accessories and brackets
| Part number | What it does | When you need it | Quote |
|---|---|---|---|
| 602RF | SDC 1 A power supply, 12 or 24 V DC field selectable, 115 V AC input, in a 10 x 10 x 4 in cabinet, with a fire/emergency release input | One door, with any kit here except the LR100ARK | Get a price |
| 631RF | SDC 1.5 A power supply, 12 or 24 V DC field selectable, 115 V AC input, in a 10 x 10 x 4 in cabinet | One door with the LR100ARK, which SDC says needs it | Get a price |
| 602RFUR1 | SDC 1 A power supply in a cabinet, with a microprocessor door controller | A simultaneous pair of doors, with any kit here except the LR100ARK | Get a price |
| 631RFUR1 | SDC 1.5 A power supply in a cabinet, with a microprocessor door controller | A simultaneous pair of doors with the LR100ARK | Get a price |
| 634RFA | SDC 4 A power supply in a large cabinet. The LR100 datasheet calls the 4 A choice 634RF | A simultaneous pair of doors, SDC's other choice | Get a price |
| LRAR1R | Adams Rite retrofit REX monitoring kit | Adams Rite 8700, 8800, 3700, 8100, 8200, 3100, 8500, 8600 and 3600 devices | Get a price |
| LRCA1R | Cal-Royal retrofit REX monitoring kit | Cal-Royal 9800 rim and GLSCVR9800 devices | Get a price |
| LRDX1R | Detex retrofit REX monitoring kit | Detex 10, 40, 20, 50, 80, 81, 62 and 63 devices | Get a price |
| LRP1R, LRP1L | PHI (Precision) retrofit REX and LS monitoring kits | Precision 2100 and 2400 rim devices | Get a price |
| LRP2R, LRP2L | PHI (Precision) retrofit REX and LS monitoring kits | Precision 2200LBR, 2800LBR and 2600 devices | Get a price |
| LRY1R, LRY1L | Yale retrofit REX and LS monitoring kits | Yale 7100, 7100-2, 7200, 7110, 7210, 7120 and 7220 devices | Get a price |
Part numbers and uses from SDC's LR100 datasheet and price sheet and its 602, 631 and 634 series datasheets and price sheets. SDC lists no monitoring kit for the Arrow S1250 or Jackson devices. We confirm every accessory in writing with the kit.
Customer reviews
No reviews yet for the SDC LR100
Reviews come only from buyers of this part, checked against their order, and we publish good and bad ones alike.
Bought this part from us? Write a review
We hold a review back only if it is abusive, defamatory or obscene, is not about the part or the order, is clearly fake, or shows someone's personal details, and we apply that test to every review. Nobody is paid or given anything for a review.
Questions about the SDC QuietDuo LR100 Electric Latch Retraction Kit
Which SDC LR100 kit fits my exit device?
The one SDC lists for your device's maker, model and opening width: for example the LR100YDK for Yale 7100 and 7200 family devices on 36 to 48 in openings, or the LR100JAK for the Jackson 2095 and 2085 on a 36 in opening. The part table on this page gives every kit with the devices SDC names for it. Send a photo of the device and its label and we confirm the kit in writing.
Is there a retrofit electric latch retraction kit for the Adams Rite 8600 and 8800?
Yes, the LR100ARK. SDC lists it for the Adams Rite 8800 and 3700 rim devices, the 8100, 8200 and 3100 surface vertical rod devices and the 8500, 8600 and 3600 concealed vertical rod devices, on 36 to 48 in openings, and it fits into the device already on the door. It retracts the latch only, not the push pad, and SDC says it needs its 631RF power supply. A 30 in opening takes the LR100ARK-EM instead, which SDC also lists for the 8700 rim device. Send a photo of the device and its label and we confirm the kit in writing.
What power supply does the SDC LR100 need?
A 24 V DC supply. SDC recommends its 602RF for a single door and the 602RFUR1 or a 634 series supply for a simultaneous pair. The LR100ARK needs the 631RF, or the 631RFUR1 or a 634 series supply for a pair. With another maker's supply, SDC recommends a linear, regulated and filtered supply rated at least 2 A per kit.
Does the LR100 retract the push pad as well as the latch?
On most kits, yes: SDC says the motor retracts the latch and pulls the push pad into the dogged position, so the door works push and pull. The LR100ARK for Adams Rite devices retracts the latch only, not the push pad.
Does an SDC LR100 kit fit the Accentra 2100?
No LR100 kit is listed for it. SDC lists the LR100YDK for Yale 7100, 7100-2 and 7200 rim devices and their 7110, 7210, 7120 and 7220 vertical rod versions, and no LR100 kit for the 2100. The 2100 in SDC's chart is the PHI (Precision) 2100, a different exit device, which takes the LR100PDK.
Can an LR100 kit go on a fire-rated exit device?
SDC describes the LR100 kits as being for panic and fire rated exit devices, says the exit device always provides uninhibited egress, and lists UL 305, UL 10C, ULC-S104 and ANSI/BHMA A156.3 Grade 1 among their certifications. Whether and how a kit may be used on your door is decided by your local code official, the Authority Having Jurisdiction (AHJ).
Does the exit device have to come off the door?
No. SDC says LR100 kits retrofit the devices it lists without removing the device from the door: the cover or end cap comes off, any mechanical dogging comes out and the kit goes into the rail. A 42 or 48 in device cut down for a narrower opening may not have room, so measure from the end of the touchpad to the end rail first.
What is the difference between an LR100 and an LR100-EM kit?
Where the controller board sits. An LR100 kit is one unit inside the rail, behind the access cover. An -EM kit is two pieces with the controller board outside the rail, which SDC says gains up to 1 in of room for devices cut down for smaller openings. On this page the LR100CAK-EM is an -EM kit; SDC also makes -EM versions of the Yale and Adams Rite kits for 30 in openings.
How do I order the SDC LR100?
- 1Choose the kit. From the table above, by the maker and model on your exit device and the opening width, or send a photo of the device and its label and we identify the kit.
- 2We confirm it in writing. Exit device, opening width, kit, power supply and whether the opening is fire rated, with the price and the total including shipping, within one business day.
- 3You approve and pay. Every order is prepaid, with no account and no minimum order. Unused stock items can be returned within 30 days with a 25 percent restocking fee; installed or wired items and special orders cannot.
- 4It ships direct. From a US distributor warehouse, tracking on every box. Stocked items ship the same or next business day after payment; special-order parts are quoted with their lead time.
Documents: data sheet, installation, power supplies and certificates
14 documents from SDC
Data sheet
Installation
- LR100ARK installation, Adams Rite rim devices 3700 and 8800
- LR100ARK installation, Adams Rite vertical rod devices 3100, 3600, 8100, 8200, 8500 and 8600
- LR100AWK installation, Arrow S1150 and S1250
- LR100CAK-EM installation and wiring, Cal-Royal 2200 and 9800 families
- LR100CAK-9800 installation, Cal-Royal GLS9800
- LR100DXK installation, Detex 10 to 80 series, with the Value Series cover change
- LR100JAK installation, Jackson 2085 and 2095
- LR100PDK installation, PHI Precision devices
- LR100YDK installation, Yale 7100 and 7200 families
Power supplies
Certificates
Links open SDC's own files. Product photo courtesy of SDC, shown for every LR100 kit on this page. Spot something wrong on this page? Email sales@latchfordhardware.com and we check it against the source.
Related
- Electrified hardware
- Rim exit devices
- Panic hardware and fire exit hardware guide
- Fail safe vs fail secure: strikes and maglocks
- Send a photo, get a quote
- Alarm Lock Trilogy DL2700 Keypad Lock
- HES™ 1006 Series Electric Strike
- HES 1500 Series Electric Strike
- HES 1600 Series Electric Strike
- HES 9600 Series Electric Strike
- Securitron® M62 Magnalock®
Not sure which LR100 you need?
Send a photo of the door, the frame and anything already installed. We tell you which part number fits and what else the door needs, within one business day.