- Home
- Buying guides
- Commercial door closer adjustment: valves, spring and closing time
Commercial door closer adjustment: valves, spring and closing time
Commercial door closer adjustment is done in two stages: set the spring power for the door, then time the swing with the sweep and latch valves and set the backcheck for a slight cushion.
On the Norton, Sargent and dormakaba closers checked here, a valve turned clockwise slows the door and counterclockwise speeds it up, and no valve is ever backed out of the body, which the makers warn makes it leak.
Last checked against the sources listed on this page.
How do you adjust a commercial door closer?
This section and those after it were checked on against the sources listed on this page.
Commercial door closer adjustment starts with the spring, then the valves: set the spring power for the door, then time the swing with the sweep and latch valves and set the backcheck for a slight cushion. On the Norton, Sargent and dormakaba closers checked here, a valve turned clockwise slows the door; counterclockwise speeds it up.
In order, from the makers’ instructions:
- Door first. Norton and Sargent call for ball bearing or anti-friction hinges; dormakaba says to make sure the door operates efficiently before the closer goes on.
- Spring power next. Norton: always adjust spring power before adjusting control. dormakaba: confirm the spring size before any closing speed adjustment.
- Sweep, then latch. Time the door from 90 degrees open. The sweep valve sets most of the swing, the latch valve the last few degrees; target times are in the ADA section below.
- Backcheck. Sargent: set it for a slight cushion, because too abrupt a check damages the closer. Norton and Sargent: never close the backcheck valve completely.
- Delayed action, where fitted. On the Sargent 281, clockwise slows the door through the delay range. Norton puts every adjustment before the cover goes on.
| Adjustment | Clockwise | Counterclockwise | Tool the maker names |
|---|---|---|---|
| Sweep (closing speed) | Slower | Faster | 1/8 in hex key (Norton CloserPlus, Sargent 281) |
| Latch | Slower | Faster | 1/8 in hex key (Norton CloserPlus, Sargent 281) |
| Backcheck | More cushion | Less cushion | 1/8 in hex key (Norton CloserPlus, Sargent 281) |
| Spring power | More closing force | Less closing force | 5/16 in socket or adjustable wrench (Norton 8000 Tri-Style); 1/4 in Allen (Sargent 281) |
How far should each valve turn?
None of the instruction sheets opened here gives a fraction of a turn; they give a target time and hard limits. Norton: backing a valve out of the closer makes it leak. Sargent: fully opened valves will leak. dormakaba: never back a valve head out beyond the casting or close a valve completely.
What do S, L and backcheck mean on a door closer?
On a door closer, S marks the sweep valve, which sets the speed of most of the closing swing, and L the latch valve, which sets the last few degrees; backcheck (BC) is hydraulic resistance on the opening swing that slows a door thrown open before it reaches its stop. Backcheck is never the stop itself.
Norton marks its valves S and L, with D for delayed action; dormakaba’s diagram labels S, L, BC, POS and DEL; Sargent names them closing speed, latching speed, backcheck and delayed action. Where each one works:
| Valve | Norton 8000 (8501) | Sargent 281 | dormakaba 8900 |
|---|---|---|---|
| Sweep (S) | Full open to about 10 degrees from closed | Closing to about 8 in from closed | Main swing, down to 15 degrees |
| Latch (L) | Last 10 degrees | Final 8 in of the swing | Last 15 degrees |
| Backcheck (BC) | Opening, from about 75 degrees | Opening, from about 70 degrees | Opening, from 65 degrees |
| Delayed action (optional) | Valve D, delay range | Holds the door open momentarily | From full open to the start of the sweep |
Backcheck cushions; it does not stop. Norton says never to close the valve completely because it is not intended to provide a positive stop, and Sargent says never to use backcheck as a door stop and always to use a door stop. Sargent’s ABC option starts the backcheck about 15 degrees sooner, and dormakaba’s POS valve moves it for parallel arms.
How do you fix a door that slams or will not latch?
A door that slams shut is closing too fast in its latch or sweep range: turn that valve clockwise to slow it. A door that stops short of the latch needs the opposite, a little more latch speed (counterclockwise) or more spring power, which Sargent says to set at the minimum force that closes and latches the door reliably.
- Slams shut. A bang in the last few degrees is the latch valve; a fast swing throughout is the sweep valve.
- Slams open. That is backcheck: clockwise adds cushion, kept slight, and a door stop is still required (Sargent).
- Will not latch. Sargent calls the latching speed adjustment critical for latching and says the closing force comes from the spring: if the door does not latch, increase power; if it is hard to open, decrease it slightly. Norton adds that the spring may need readjusting once the sweep and latch are set.
- Low opening force. Norton and dormakaba warn that a closer adjusted to a reduced opening force may not close and latch reliably, Norton naming wind gusts and building stack pressure; Sargent, that high power set to beat strong drafts may exceed ADA standards.
Does cold weather change a closer’s adjustment?
The makers say their fluid is made not to need it: Norton rates its NorGlide fluid stable down to minus 40 degrees F, Sargent says the 281 works in extreme temperatures without readjustment, and BEST designs its HD7000 to minimize change in closing speed during severe temperature changes. Norton and Sargent both rule out mounting a closer on the weather side of an exterior door (Sargent: it voids the warranty); for strong drafts, Sargent’s answer is more spring power.
We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.
Can you change a door closer’s size on site?
Yes, on a multi-size closer. The Norton 8501, Sargent 281 and dormakaba 8916 each adjust through sizes 1 to 6 by turning one spring screw or shaft, clockwise for more closing force and counterclockwise for less. Set the spring before the valves, as Norton and dormakaba direct, and treat the maker’s turns chart as a guide.
| Closer | Turned with | Shipped at | Range in the maker’s chart |
|---|---|---|---|
| Norton 8501, Tri-Style pack | Power adjustment shaft, 5/16 in socket or adjustable wrench | Mid range, 10 full turns | 5 to 18 full turns by door width, interior or exterior and arm; 20 turns maximum |
| Sargent 281 | 1/4 in Allen spring power adjusting screw | Size 3 | From 1 to 5 turns counterclockwise (32 to 40 in interior doors) to 19 clockwise (exterior doors over 48 in), counted from the factory setting |
| dormakaba 8916 | Spring force adjustment | Size 4 | Size 2 at 20 full turns down, size 6 at 12 up, on a regular or top jamb mount |
Sargent says the door must be open while the spring is adjusted, and that a power drill voids the warranty. Not every body adjusts: dormakaba’s 8907 has a fixed size 7 spring and no power adjustment. Norton’s CloserPlus version, the CLP8501, has its own chart by door width on our Norton 8501 door closer page. BEST’s HD8016 also adjusts from size 1 to 6. Which size a door needs is in types of door closers and how to choose one.
How do you set a door closer to the ADA closing speed and opening force?
Where the 2010 ADA Standards apply, section 404.2.8.1 requires a closer adjusted so the door takes at least 5 seconds to move from 90 degrees open to 12 degrees from the latch, and section 404.2.9 limits the force to open an interior hinged door to 5 pounds (22.2 N).
Section 404.2.9 leaves fire doors at the minimum opening force the appropriate administrative authority allows, sets no figure for exterior hinged doors and excludes the force to retract a latch bolt. The makers time doors differently:
| Source | Closing time | Timed from |
|---|---|---|
| 2010 ADA Standards, 404.2.8.1 | 5 seconds minimum | 90 degrees to 12 degrees from the latch |
| Norton 8000, Tri-Style arms (80-9380-2206-020) | 3 to 7 seconds | 90 degrees to closed |
| Norton 8000, CloserPlus and PR arms (80-9380-2209-020) | 4 to 7 seconds | 90 degrees |
| Sargent 281, CPS arms (A7319F) | 6 seconds minimum | 90 degrees to closed |
| Sargent 281, hold open arms (A7313E) | 3 to 6 seconds | 90 degrees to closed |
| dormakaba 8900 (08279150) | 3 to 6 seconds | 90 degrees |
So several makers’ ranges start below 5 seconds, and the ADA clock stops 12 degrees short of the latch while the makers’ clocks run to closed: a door timed at exactly 5 seconds to closed reaches 12 degrees in under 5. Norton and Sargent both say elderly or disabled users may need a longer closing time (Norton adds small children), and Sargent recommends its alternate regular arm mounting position for ADA compliant doors.
For opening force, dormakaba’s 8916 instructions say to take an opening force reading from the pull on the door and adjust the spring until the barrier-free force is met. The rest of section 404 is in our guide to ADA door requirements.
We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.
Does a regular, parallel or top jamb mounting change the adjustment?
Yes, in three ways: a parallel arm needs more spring turns for the same door, regular and top jamb mountings carry an extra power adjustment at the arm, and some closers move the backcheck for a parallel arm. Which arm suits an opening is covered in types of door closers and how to choose one.
- More turns on a parallel arm. For a 36 in interior door, Norton’s 8000 Tri-Style chart gives 8 full turns on a regular arm or top jamb and 10 on a parallel arm. For a 36 in exterior door, Sargent’s 281 chart gives 5 to 8 turns clockwise from the factory setting on a standard or top jamb mount and 7 to 11 on a parallel arm. dormakaba’s 8916 chart takes a 3 ft interior door from size 3 on a regular or top jamb mount to size 4 on a parallel one.
- Power at the arm. On regular arm and top jamb mountings, Norton’s arm shoe has positions that make the closer 7-1/2% stronger or 7-1/2% weaker, and Sargent adds closing power by moving the foot pivot to the hole nearest the hinge.
- Backcheck on a parallel arm. dormakaba ships the 8900’s backcheck positioning valve on, says it must stay on for parallel arm mounts, and says it advances the backcheck about 15 degrees. BEST offers an advanced variable backcheck (AVB) to keep an effective backcheck range on parallel arm applications.
Arms and brackets are under regular, parallel and top jamb arms.
Can a door closer leaking oil be fixed?
A door closer leaking oil is replaced, not adjusted. None of the maker documents opened here gives a way to reseal or refill a closer: Sargent’s parts manual lists the 281 closer body as one part, with no seals or fluid, and dormakaba says a closer must be replaced once its functional reliability can no longer be ensured.
- How closers come to leak. Norton: do not back valves out of the closer or a leak will result. Sargent: do not completely open the valves, which will leak. dormakaba: do not back a valve head out beyond the closer casting. dormakaba’s safety advice, written for its UK market, lists a broken closer losing hydraulic fluid among the consequences of misuse, such as the wrong closer size or a door hindered by sticking seals or misaligned hinges.
- A door the spring cannot close. Norton’s catalog says wind, stack pressure or a door taller or heavier than its 1-3/4 in by 7 ft chart door may need a different spring setting, a larger size closer or a different closer. BEST’s HD8056 and dormakaba’s 8956 run from size 5 to 6 plus 50% for exceptionally wide, tall or heavy doors.
Choosing the replacement by size and arm is in types of door closers and how to choose one. The Norton 8501 door closer we list adjusts through sizes 1 to 6 on doors 28 to 48 in wide; others are under surface closers, Grade 1 and 2. Send a photo of the old closer, its arm and the frame head, and we identify it and quote the same business day.
What do we confirm before it ships?
Before anything ships we confirm in writing: the closer series and size, the arm and mounting (regular, parallel or top jamb), the finish, and the door’s hand where it matters, read from a photo of the closer and its label.
Sources
The numbers and code sections on this page come from these documents, opened on the date above.
- Norton Rixson 8000 Series door closer, regular, top jamb or parallel arms, non-hold open, installation instructions (80-9380-2206-020 Rev 5, 07/26, AADSS1015225)
- Norton Rixson 8000 Series parallel rigid (PR) or CloserPlus (CLP) arm installation instructions (80-9380-2209-020 Rev 3, 11/23, AADSS1056605)
- Norton Rixson Surface Closers catalog: 8301/8501 section, sizing notes and NorGlide fluid (43506-07/26, AADSS1193131)
- SARGENT 281 Series closer with regular arms (without holder), installation instructions (A7278F 12/22 Rev 6, AADSS1055047)
- SARGENT 281 Series closer with CPS/CPSH arms, installation instructions (A7319F 12/22 Rev 6, AADSS1055038)
- SARGENT 281 Series non-handed closer, hold open arms 25-H, 25-HZ, 25-HZA, 25-PH9, installation instructions (A7313E 12/22 Rev 5, AADSS1055044)
- SARGENT 281 Series Powerglide door closer catalog: general information (90119, 09/26, AADSS1004565)
- SARGENT 281, 351 and 1431 Series parts manual (90902, 10/25, AADSS1061306)
- dormakaba 8900 AF/AFJ/AFP flat arm, regular, top jamb and parallel, installation instructions (08279150, 09-2019)
- dormakaba 8900 Series surface applied door closers brochure (DHW_1680_BR_EN, 03/25)
- dormakaba (Dorma UK), Product information and safety advice: door closer systems with hydraulic damping
- BEST Surface Applied Door Closers catalog: HD8000, HD7000 and SL6000 (KAA1426, 03-23)
- 2010 ADA Standards for Accessible Design, sections 404.2.8 closing speed and 404.2.9 opening force, with advisory (ADA.gov)
Related buying guides
Not sure which part you need?
You do not need a part number. Send a photo of the hardware and the door it sits on, plus the ship-to zip code, and we will identify it and quote it the same business day.