  3. Types of door closers and how to choose one

Types of door closers and how to choose one

The types of commercial door closer are surface closers, mounted on the door or frame with a regular, parallel or top jamb arm; concealed closers, hidden in the frame head or the door's top rail; and floor closers set in the floor under a pivot-hung door.

After the type, a closer is chosen by its ANSI/BHMA A156.4 grade, the size the door needs and whether the opening is fire rated.

This answer was checked on against the sources listed on this page.

What decides the part number?

The grade, the size the door needs, the arm the opening allows and whether it is a surface or floor closer decide the part number.

What is a Grade 1 door closer?

A Grade 1 door closer meets the heavy duty grade of ANSI/BHMA A156.4, the standard for door closers; Sargent’s 281 Series, for example, is certified to Grade 1. Choose Grade 1 for main entrances, stairwells and other high traffic openings.

What size closer does the door need?

Closer size is set by door width and weight. Adjustable closers cover a range of sizes, which is why one part number can replace several older fixed size units.

Which closer arm fits the opening?

A regular arm mounts on the pull side and projects furthest. A parallel arm mounts on the push side and tucks in against the door. A top jamb arm mounts on the frame face. The arm decides whether a closer physically fits.

Surface closer or floor closer?

A surface closer mounts on the door or frame and is the common replacement. A floor closer sits in the floor under a pivot-hung door, often a heavy or glass door, and is replaced with the same pattern because the floor is already cut for it.

What does a fire rated opening need?

A fire rated opening needs a closer listed for that door. Whether a hold open is allowed on it, and how the hold open must release, is set by the codes your building follows. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

What finish do closers come in?

Closers usually come in BHMA 689 aluminum, which Sargent’s and Pemko’s finish charts list as a paint or powder coat, not a plating.

What are the types of door closers?

This section and those after it, unless dated otherwise, were checked on against the sources listed on this page.

The types of door closers are surface mounted, concealed in the door, overhead concealed and concealed in the floor: the four types ANSI/BHMA A156.4, the American National Standard for door closers and pivots, sorts by where the closer is mounted. Electromagnetic and electromechanical closer-holders, which hold the door open until they release it, have their own standard, ANSI/BHMA A156.15.

One example of each, with the maker’s own limits:

TypeWhere it sitsExample and limits
Surface mountedOn the door or frame face, with a regular, parallel or top jamb arm, or a slide trackNorton 8000 Series: sizes 1 to 6, doors to 250 lb
Overhead concealedIn the frame head, its slide track hidden in the door’s top railNorton Rixson 7900: 4 in high header; doors 27 in wide or more, to 200 lb
Concealed in the doorInside the top rail (the same model also mounts in the frame)Norton Rixson 61: interior doors only, to 42 in wide and 175 lb, weight carried by the hinges
Concealed in the floorIn a cement case in the floor; the door hangs on the closer’s bottom arm and a top pivotRixson 27: doors to 4 ft wide and 450 lb; the L27, for lead-lined doors, to 1,500 lb

Surface vs concealed vs floor closer: which one?

A surface closer gives the most mounting choices, because one body can take all three arms: Norton’s Tri-Style 1600 and 8501 and BEST’s HD8000 come with the parts for regular, top jamb and parallel mounting. A floor closer carries the door’s weight, which Rixson says reduces stress on the frame and eliminates sag; for existing installations Rixson supplies its floor closers without the cement case.

Unlike most surface closers, the 7900 and every single acting Rixson floor closer are handed, so the hand goes on the order (see the door handing chart). Replacements are on our floor closers page.

Grade 1 vs Grade 2 door closer: what is the difference?

A Grade 1 door closer has passed the highest of the three performance levels in ANSI/BHMA A156.4, and a Grade 2 closer has passed the level below it. BHMA, which maintains the standard, states that a Grade 1 closer must pass two million cycles of opening and closing on a test door of a specified weight.

BHMA’s public summary gives only the Grade 1 cycle figure; the Grade 2 and 3 thresholds are in the full standard, which BHMA sells. Besides cycles, BHMA lists tests of door control (closing speeds, checking, overload abuse, opening angle), closing force and finish, the last by salt spray to ASTM B117. The tests run at neutral air pressure and 60 to 85 degrees F, and BHMA says results in use vary with installation, maintenance, wind and pressure differences.

For scale, Norton Rixson estimates yearly openings at about 1,500,000 for a large department store entrance, 225,000 for a school entrance and 22,000 for an office corridor door.

In the catalogs checked here, Grade 1 is the norm. BEST’s HD8000, HD7000 and SL6000 are all Grade 1. Norton’s comparison chart lists nine of its eleven surface series as Grade 1 and the compact 1700 as Grade 3, gives the 78-B/F no grade, and lists none as Grade 2. The concealed Norton Rixson 91 and 7900 and the Rixson 27 floor closer are Grade 1 too.

Check the grade in the maker’s catalog and in BHMA’s Certified Products Directory. A grade is neither a fire listing nor a size. The Norton 8501 door closer we list is Grade 1; others are on our surface closers, Grade 1 and 2 page.

What size door closer do I need?

The size a door needs is read from the maker’s sizing table by door width, interior or exterior, and arm. Size is spring power, numbered 1 to 6 under ANSI/BHMA A156.4; Norton’s 8000 and 7500, Sargent’s 281 and BEST’s HD8000 adjust through all six on site. Setting the spring power and valves on site is covered in commercial door closer adjustment.

Norton’s tables for its 1600 storefront closer show what the number buys:

Norton 1600 modelRegular arm or top jambParallel arm
Size 3 (1603BC)Interior doors to 38 in wide, exterior to 30 inInterior to 36 in, exterior to 30 in
Size 4 (1604BC)Interior to 42 in, exterior to 36 inInterior to 42 in, exterior to 36 in
1601, adjustable 1 to 6Interior and exterior to 48 inInterior and exterior to 48 in

The same size closes a narrower door outside than inside, and a parallel arm can need a size more: in these tables a 38 in interior door takes size 3 on a regular arm but size 4 on a parallel arm. Norton and Sargent base their charts on 1-3/4 in thick, 7 ft standard weight doors swinging to 110 degrees; taller or heavier doors may need a larger size.

Weight is its own limit: 250 lb for Norton’s 8000 and Sargent’s 281, 180 lb for BEST’s HD8000. Norton Rixson estimates a door’s weight as its area times a weight per square foot: 6.5 lb for 1-3/4 in hollow metal, 7 lb for 1-3/4 in solid core wood, 3.5 lb for an aluminum and glass storefront door, 7 lb for 1/2 in tempered glass. Its own example: a 3 ft 6 in by 8 ft door of 1/2 in tempered glass is 196 lb.

Sargent notes the spring setting decides both the closing force and the force needed to open the door. Where the 2010 ADA Standards apply, section 404.2.9 limits that opening force on interior hinged doors to 5 pounds maximum to push or pull the door open. It sets no figure for exterior hinged doors and leaves fire doors to the minimum opening force the appropriate administrative authority allows. Norton, Sargent and BEST each warn that a closer set for low opening force may not close and latch the door reliably; Norton and Sargent name wind gusts and building stack pressure. The Norton 8501 we list covers sizes 1 to 6 on doors 28 to 48 in wide.

We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

Parallel arm vs regular arm: which does the door need?

Which arm a door needs depends on which side the closer can go, the weather and the top rail: a regular arm puts the closer on the pull side of the door and is, in Norton’s words, the most power-efficient application. A parallel arm puts it on the push side with the arm almost parallel to the door, which looks neater and suits vandal-prone doors, but Norton rates it about 25% less power-efficient than a regular arm.

Top jamb, the third mounting, puts the closer on the frame face above the door, on the push side, and Norton ranks it the best alternative to a regular arm for efficiency. With the minimums from Sargent’s 281 catalog:

MountingCloser bodySideSargent 281 minimums
Regular armOn the doorPull1-1/2 in frame face, 2-5/8 in door top rail
Top jambOn the framePush4-3/8 in frame face, or 1-7/16 in with the 281-B plate; 1-7/8 in top rail
Parallel armOn the doorPush4-3/8 in top rail with 6-7/8 in unobstructed (P9 arm)

What usually decides it:

  • An exterior door that swings out. Sargent says to keep the closer out of the weather and lists top jamb for exterior doors opening out; Norton calls top jamb the best door control for them. Both makers tie the warranty to installing the closer on the inside of the building.
  • A corridor or public side. A parallel arm does not project into the room (Sargent), and BEST’s suggested specification puts closers on the non-public side of the door and the stair side of stair doors, unless the hardware schedule says otherwise.
  • A narrow top rail. In Sargent’s minimums a top jamb needs the least rail on the door and a parallel arm the most.

Whatever the arm, Sargent says a positive stop is required, because backcheck cannot be used as one. See regular, parallel and top jamb arms and tracks and spring stops.

Can I put a hold-open closer on a fire door?

Not with a mechanical hold-open arm. Norton states that hold open arm door closers are not permitted on fire door assemblies, and Sargent’s UL listing covers its closers “for self-closing doors without hold-open feature”. For a fire door that has to stand open, makers offer closer-holders that close it when an alarm is signaled or the power fails.

  • Listing. ANSI/BHMA A156.4 (2019, section 1.3) requires a closer on a labeled fire door assembly to be listed or labeled by a nationally recognized independent testing laboratory, with periodic in-plant follow-up. Norton lists its 8000 Series to UL 10C positive pressure for up to 3 hours; Sargent lists the 281 for use on fire rated doors.
  • Floor closers. Rixson’s fire rated package, for assemblies up to 3 hours, is a non-hold open closer with steel top and intermediate pivots. Rixson says center hung floor closers are not for fire rated doors, and its low opening force closers not for labeled fire doors.
  • Closer-holders. dormakaba’s 1800 Series, certified to ANSI/BHMA A156.15 and UL listed, holds the door open or lets it swing free, and closes it when the current is interrupted or an alarm is signaled; without power it works as a standard closer.
  • Doors that are not fire rated. Sargent advises friction hold-open arms for moderate use and positive stop hold-open arms for doors held open repeatedly. The Norton 8501’s thumbturn hold open version, the CLP8501T, is for these doors only.

Nothing on this page is quoted from NFPA 80, the fire door standard. Closers listed for fire doors are on our fire rated closers page. What the rest of a fire door needs, part by part, is under fire rated door hardware in our when is panic hardware required guide.

We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

What do we confirm before it ships?

Before anything ships we confirm in writing: hand of door, mounting position and arm, door width and weight, surface or floor closer, and whether the opening is fire rated.

AvailabilityNorton 7500 and 1600, BEST EHD9000, Rixson 27 and 28 floor closers, Sargent and dormakaba, about 1,100 part numbers including arms and tracks. Some lines are stocked at our distributors. Most are special order from the manufacturer, typically 4 to 6 weeks and sometimes longer, and the quote states it.
How this guide is checked

Every figure in this guide comes from the documents listed below: manufacturers' catalogs, templates and installation instructions, standards bodies' summaries, and the published code text with its official guides. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

Not sure which part you need?

You do not need a part number. Send a photo of the hardware and the door it sits on, plus the ship-to ZIP code, and we will identify it and quote it within one business day.