When is panic hardware required? Exit devices explained

Panic hardware is required on swinging doors serving a Group H occupancy, and on swinging doors serving rooms or spaces with an occupant load of 50 or more in a Group A or Group E occupancy (2021 IBC section 1010.2.9, section 1010.2.8 in the 2024 IBC).

The trigger is the occupant load of the room or space the door serves, not how many people use that door, and your Authority Having Jurisdiction (AHJ) makes the final call.

This answer was checked on against the sources listed on this page.

What decides the part number?

The device type, the door width, whether the opening is fire rated and the outside trim decide the part number.

Which type of exit device do I need?

Choose by how the door must latch: a rim device latches into a strike on the frame, surface and concealed vertical rod devices latch at the top and bottom of the door and suit pairs, and a mortise exit device works a lock case in the door edge.

What is the difference between panic hardware and fire exit hardware?

Fire exit hardware is panic hardware that is also listed for fire doors, and it is made without mechanical dogging so the door latches every time it closes: on Sargent’s 80 Series, dogging comes only on devices that are not fire rated. They look similar and are not interchangeable.

How is an exit device sized?

An exit device is sized to the door width: each device is made for a range of widths. Measure the door, not the frame, because a device sized for the wrong width will not mount correctly.

What goes on the outside of the door?

The outside trim is blank, a pull or a lever. On night latch trim a key retracts the latch; on classroom or storeroom lever trim a key unlocks the lever.

Which doors need panic hardware?

Panic hardware is required on doors serving Group A assembly or Group E educational spaces with an occupant load of 50 or more, and on doors serving Group H high hazard occupancies. The trigger is the occupant load of the space the door serves, not how many people use that door. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

Which electrical and energy rooms need panic hardware?

The 2024 IBC also requires panic or fire exit hardware on doors serving transformer vaults, battery or energy storage rooms and modular data centers, and on doors less than 25 feet from the working space of electrical equipment rated 800 amperes or more; those doors must swing in the direction of egress. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

What listing does panic hardware need?

The 2018 IBC required panic hardware listed to UL 305, and fire exit hardware listed to UL 10C and UL 305, with the push bar at least half the door width (section 1010.1.10.1).

Can an electric lock go on a door with panic hardware?

BHMA reads the 2024 editions as not permitting a sensor release on a door that is required to have panic hardware. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

How do you work out if a room’s occupant load is 50 or more?

This section and those after it, unless dated otherwise, were checked on against the sources listed on this page.

For a room without fixed seats, divide its floor area by the occupant load factor for its use (2021 IBC section 1004.5). In the 2024 IBC’s Table 1004.5, an assembly room with chairs only, not fixed, reaches 50 occupants at 350 net square feet, one with tables and chairs at 750, and a classroom at 1,000. At 50 or more in a Group A or E occupancy, the panic hardware rule covers the swinging doors serving that room (2021 IBC 1010.2.9, 2024 IBC 1010.2.8).

Occupant load factors from 2024 IBC Table 1004.5 and the floor area that calculates to 50 occupants
Use of the space (Table 1004.5)Square feet per occupantFloor area that calculates to 50
Assembly without fixed seats: standing space5 net250 sq ft net
Assembly without fixed seats: concentrated (chairs only, not fixed)7 net350 sq ft net
Assembly: gaming floors (keno, slots and similar)11 gross550 sq ft gross
Assembly without fixed seats: unconcentrated (tables and chairs)15 net750 sq ft net
Educational: classroom area20 net1,000 sq ft net
Assembly: exhibit gallery and museum30 net1,500 sq ft net
Educational: shops and other vocational room areas50 net2,500 sq ft net
Assembly with fixed seatsSee section 1004.6Not worked from floor area

The last column is our arithmetic, 50 times the factor. Minnesota’s Department of Labor and Industry lists one 2024 change to the table, a new information technology row.

  • Fewer by design: where the building official approves, the actual number a space is designed for may be used if lower (2021 IBC 1004.5, exception 1).
  • The posted sign: 2021 IBC 1004.9 has an assembly room’s occupant load posted near its main exit or exit access doorway, so read that first.
  • No threshold: Group H doors fall under the rule at any occupant load, and refrigeration machinery room exit and exit access doorways get panic hardware “regardless of the occupant load served” (2021 IBC 1006.2.2.2).

We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

When can a door that needs panic hardware be locked?

The panic hardware rule lists four cases in which its doors may be locked (2021 IBC 1010.2.9, 2024 IBC 1010.2.8): a Group A main exit with a key-operated lock and a sign, electrical locking, exit access doors from occupied outdoor areas, and courtrooms. Otherwise those doors “shall not be provided with a latch or lock other than panic hardware or fire exit hardware.”

The four exceptions to the IBC panic hardware rule
ExceptionSection it points toWhat that section allows
1. A main exit of a Group A occupancy1010.2.4, item 3Key-operated locking from the egress side in Group A buildings with an occupant load of 300 or less, the lock readily distinguishable as locked, with a sign reading THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED in 1 inch letters; the building official can revoke it for due cause. The 2024 text adds: main exterior doors of the building or main doors of the tenant space only.
2. Doors with panic or fire exit hardware, Group A or E1010.2.10 in 2024; 1010.2.11, door hardware release, in 2021Electrical locking, keeping the panic hardware. The 2024 exceptions do not cite sensor release (2024 section 1010.2.11). For the conditions, see fail safe vs fail secure.
3. Exit access doors serving occupied exterior areas1010.2.4, item 8In the 2021 text, other than at egress courts: a key-operated lock, the maximum occupant load posted, a weatherproof telephone or two-way communication system outside at least one door, a clear window or glazed opening of at least 5 sq ft at each door, an unlock sign, and no more than 300 occupants outside.
4. Courtrooms1010.2.13, item 3 in 2021 (1010.2.12 in 2024)Delayed egress locking in Group A-3 and B courtrooms, on doors other than the main exit or exit access door, in buildings sprinklered throughout (section 903.3.1.1).

Minnesota’s Department of Labor and Industry maps 2021 sections 1010.2.11 through 1010.2.13 onto 2024 sections 1010.2.10 through 1010.2.12. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

What is fire rated door hardware?

This section was checked on against the sources listed on this page.

Fire rated door hardware is hardware listed by a testing laboratory for use on a labeled fire door assembly, on a door that has to close and latch by itself: the 2024 IBC says “Fire doors shall be latching and self- or automatic-closing” (section 716.2.6.1). Each part carries its own listing, and a lock’s ANSI/BHMA grade is not one: BHMA says hardware for fire doors is evaluated and listed to UL 10C by an accredited third-party testing laboratory.

Fire ratings the makers state, part by part, on hardware this site covers
PartWhat the maker or standard saysOn this site
Door closerANSI/BHMA A156.4 (2019, section 1.3): a closer on a labeled fire door assembly is listed or labeled by a nationally recognized independent testing laboratory. Norton lists its 8000 Series to UL 10C positive pressure up to 3 hours and says hold open arm door closers “are not permitted to be used on fire door assemblies”. A fire door that must stand open takes a closer-holder, such as dormakaba’s 1800 Series, which closes the door when the current is interrupted or an alarm is signaled.Types of door closers, Norton 8501 door closer
Exit deviceFire exit hardware: panic hardware that also carries a fire listing, with no mechanical dogging (next section).Accentra 2100 rim exit device (2100F)
Lock or latchBEST lists the 9K Series for 3 hour A label single or double swinging doors. Alarm Lock lists the Trilogy DL2700 latchbolt as UL listed and fire rated for 3 hours.BEST 9K Series cylindrical lock, Alarm Lock Trilogy DL2700
Electric strikeHES rates the 1006, 1500 and 1600 at 3 hours on a single door and 1.5 hours on a pair, fail secure only, under UL 10C. It lists the 9600 as non-fire rated.Fail safe vs fail secure, electric strikes
MaglockUL lists the Securitron M62 with the B, D, BD or F suffix as an auxiliary lock for fire doors rated up to 3 hours, and other versions up to 1 hour. A maglock does not latch, so the door still needs its own latching hardware.Securitron M62 Magnalock
Hinges and pivotsHager: steel and stainless steel hinges may be used on listed fire rated or labeled openings, brass may not, and its electric hinges are UL tested for them. Rixson: pivots for fire rated doors up to 3 hours include a steel top pivot and must have steel intermediate pivots.Types of door hinges
Astragal on a pairPemko marks its fire rated, listed products with a symbol for UL 10B and UL 10C, and its split astragals carry it.ADA threshold height, door bottoms, seals and astragals

Sargent and Accentra both warn that field changes to a fire-rated opening can affect its rating (next section). Nothing on this page is quoted from NFPA 80, the fire door standard. Give the door’s fire rating with your quote request.

We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

Panic hardware vs fire exit hardware: what changes on a fire-rated door?

Fire exit hardware is panic hardware that also carries a fire listing, and it cannot be dogged with a key: Sargent and Accentra offer hex key or cylinder dogging only on devices that are not fire rated. The 2018 IBC called for panic hardware listed to UL 305 and fire exit hardware listed to UL 10C and UL 305 (section 1010.1.10.1).

Panic hardware vs fire exit hardware on Sargent 80 Series and Accentra 2100 devices
PointPanic hardwareFire exit hardware
Listing in the 2018 IBCUL 305UL 10C and UL 305
Maker’s markingAccentra 2100: Panic Label, UL category FVSR. Sargent: no fire prefixAccentra 2100F: Fire Label, UL category GXHX. Sargent: the 12- prefix
Mechanical doggingSargent: hex key standard, 16- for cylinder dogging, LD- for none. Accentra: a quarter-turn dogging keyNone: Sargent’s 12- is not available with 16- or HK-; Accentra’s fire bars are non-dogging and its fire devices take a hole plug
Holding the latch back for trafficDogging, or an electric optionBy an electric option: Sargent’s 56- latch retraction “can be dogged continuously on fire-rated devices that are tied into the building’s fire detection system”, and its 58- electric dogging is listed for panic and fire, the latches extending when power is cut
Fasteners (Accentra)Sex nuts and bolts optionalSex nuts and bolts furnished standard
Fire rating in the makers’ chartsNoneSargent on metal doors: 3 hours, single doors up to 4 x 10 ft, pairs up to 8 x 10 ft (1-1/2 hours for a rim pair on the 12-L980 mullion). Accentra 2100F: 3 hours, single 4 x 8 ft, pair 8 x 8 ft with the M200F mullion

Parts do not cross over: Accentra allows only fire-rated components on fire-rated exit devices, and a component bearing the UL fire mark cannot be supplied separately and keep its rating without re-certification. Both makers warn that field changes to a fire-rated opening can affect its rating. See fire exit hardware and the Accentra 2100 rim exit device (2100 panic, 2100F fire).

We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

What are the types of panic bars?

There are four types of panic bar, named for how they latch: a rim device latches at one point into a strike on the frame, a mortise device works a lock case in the door edge, and surface and concealed vertical rod devices latch top and bottom, with the rods on the door face or inside the door. Sargent also makes a center and top latching variant.

Types of panic bars, with Sargent 80 Series examples
TypeWhere it latchesDoorsSargent 80 Series
Rim exit devicesOne point: a rim latch into a strike on the face of the frameSingle doors; pairs with a mullion8800, stiles of 4-1/2 in or more; 8500 narrow design, stiles down to 2 in without trim, such as aluminum full glass doors. Also the Accentra 2100
Mortise exit devicesOne point: a guarded latch in a mortise lock caseSingle doors; a pair, with a vertical rod device on the other leaf8900; 8300 narrow design
Surface vertical rodTop and bottom, rods on the door faceSingle doors and pairs8700; the NB8700 latches at the top only, with no bottom strike to trip on
Concealed vertical rodTop and bottom, rods inside the door; NB- leaves out the bottom rodSingle doors and pairsMD8600 for metal, AD8600 for aluminum, WD8600 for wood doors; MD8400 and AD8400 narrow designs
Center and top latchingA stainless steel center bolt and a concealed top bolt, no bottom rodLS8600 single doors; LP8600 and LR8600 pairsFactory prepped 1-3/4 in metal doors only

Both rod types are on surface and concealed vertical rod, and the mullions rim pairs need are under alarmed exits, trim and mullions. Length follows the door width: Sargent’s rails come in E (24 to 32 in doors), F (33 to 36), J (37 to 42) and G (43 to 48), cut at the factory when the width is given; the LS, LP and LR8600 fit only 36, 42, 44, 46 or 48 in doors.

How high is a panic bar mounted, and how hard can it be to push?

The 2021 IBC puts door handles, pulls, latches, locks and other operating devices 34 to 48 inches above the finished floor (section 1010.2.3) and caps the force to unlatch push or pull hardware at 15 pounds (section 1010.1.3). The makers’ standard heights sit inside that band: 41 in to the centerline on Sargent’s 80 Series, 39-15/16 in on the Accentra 2100.

Mounting height, operating force and bar length for panic hardware
MeasureFigureSource
Operating device height34 to 48 in above the finished floor2021 IBC 1010.2.3
Sargent 80 Series centerline41 in (1041 mm); 38 in (965 mm) for elementary schools on the 8900 and MD8600Sargent catalog
Accentra 2100 centerline39-15/16 in (1014 mm) above the finished floorAccentra installation instructions
Force to unlatch15 lb (67 N) for push or pull hardware; 28 inch-pounds (315 N-cm) for rotating hardware2021 IBC 1010.1.3; 2018 IBC 1010.1.10.1 for panic hardware
Force to open5 lb (22 N) on manually operated interior swinging egress doors that are not fire rated; otherwise 30 lb (133 N) to set the door in motion and 15 lb (67 N) to open it fully2021 IBC 1010.1.3
Motions to unlatchOne, in a single linear or rotational direction, releasing all latching and all locking devices; the section lists exceptions2021 IBC 1010.2.1
Push bar lengthActuating portion at least half the width of the door leaf2018 IBC 1010.1.10.1 (1010.2.9.3 in 2021, 1010.2.8.3 in 2024)
Balanced doorsPush-pad type, the pad no more than half the door width from the latch side2018 IBC 1010.1.10.2 (1010.2.9.4 in 2021, 1010.2.8.4 in 2024)

Minnesota’s Department of Labor and Industry lists both 2018 sections as renumbered, with non-substantial or editorial changes only. Sargent offers a 5 lb pressure release (option 5CH-) on its 8800, 8500, 8600 and 8400 devices. On an accessible route, the 2010 ADA Standards also limit the force to work door hardware to 5 pounds (sections 404.2.7 and 309.4); see ADA door requirements.

We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

Which outside trim does an exit device need?

Pick the outside trim by what someone outside must be able to do: nothing (exit only, ANSI function 01), use a pull or dummy lever that does not work the latch (02), retract the latch with a key (night latch, 03), use a lever a key locks and unlocks (08), unlock the lever with a key and have it relock when the key is removed (storeroom, 09), or use a lever that always works (passage, 14). Sargent and Accentra print these ANSI numbers beside their own.

Exit device trim functions by ANSI number on the Sargent 8800 and Accentra 2100 rim devices
ANSIWhat the outside doesSargent 8800Accentra 2100
01Nothing: exit onlyFunction 10620F blank plate, or no trim
02Pull or dummy lever; the latch is not worked10 with pull-only trim, or 40214F pull plate; 629F rigid dummy lever
03Night latch: a key retracts the latch04213F or 217F pull; 621F or 627F lever
08Classroom: a key locks and unlocks the lever13626F
09Storeroom: a key unlocks the lever, which relocks when the key is removed06626F, modified at installation
14Passage: the lever always works15628F

Trim is ordered by the door’s hand (both makers’ examples show RHR): see the door handing chart. Sargent’s electrified trim comes fail safe, lever unlocked with the power off (73), or fail secure, lever locked (74), at 12 or 24 V DC: see fail safe vs fail secure.

What do we confirm before it ships?

Before anything ships we confirm in writing: hand, device type, device length against the actual door width, fire rating, trim, and the cylinder keyway if it must match existing keys.

AvailabilitySargent 80 Series, BEST, dormakaba, Detex, Hager, Accentra, Adams Rite, PAMEX and Corbin Russwin, about 2,700 part numbers. A few stocked lines ship the same or next business day. Most are special order from the manufacturer, typically 4 to 6 weeks and sometimes longer, and the quote states it.
How this guide is checked

Every figure in this guide comes from the documents listed below: manufacturers' catalogs, templates and installation instructions, standards bodies' summaries, and the published code text with its official guides. We supply listed hardware and confirm in writing the part number and options you have chosen. We are not code consultants; your Authority Having Jurisdiction (AHJ) makes the final call.

Sources

The numbers and code sections on this page come from these documents, opened on the check dates shown above.

Not sure which part you need?

You do not need a part number. Send a photo of the hardware and the door it sits on, plus the ship-to ZIP code, and we will identify it and quote it within one business day.